Summary for Test 2025-09-04-21-26
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1000902 DEA: 07387904 EFIS: 0722000235 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-118-T18.4/T18.8 |
| Award Date | 03/18/2025 |
| Closeout Date | Not set |
| Work Description | INSTALL CHAIN LINK RAILING (TYPE 7 MODIFIED). |
| Location Description | VENTURA COUNTY IN MOORPARK FROM 0.2 MILE NORTH OF ROUTE 23 TO 0.1 MILE NORTH OF PRINCETON AVENUE UNDERCROSSING. |
| QA Service Level | 1 (Verified on 03/11/2025) |
Sample Information
| Sample Taken Date | 09/04/2025 | Sample Unique Key | 21 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/16/2025 |
| Sample type | Quality Assurance | A brief description of the sample | Anchor Rods, Nuts, Washers |
| The quantity of what the sample constitutes | 2703 ATR 5463N 4465W 992W | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | QA Steel Inspector | Telephone number of sampler | 7073428602 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-035-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 8000016390 5806550105 42434420 A82280 | Nut Mfg. Lot Number(s) | 42560-5806550105 |
| Washer Mfg. Lot Number(s) | E7784, E8078 | Bolt Specification | F1554 Grade 55 |
| Bolt Length(s) | 12" | Nut Specification | ASTM 563 Grade DH |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-09-04-21
DIME Test ID: 2025-09-04-21-26
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2025-10-14
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 10/14/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 42560-5806550105 | .625 | 33900 | 0000 | A563 Proof Load | Kleinfelder |
| 2 | 1B | 42560-5806550105 | .625 | 33900 | 0000 | A563 Proof Load | Kleinfelder |
| 3 | 1C | 42560-5806550105 | .625 | 33900 | 0000 | A563 Proof Lo | Kleinfelder |
| 4 | 1D | 42560-5806550105 | .625 | 33900 | 0000 | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2025 ✔