Summary for Test 2025-03-24-124-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1001110 DEA: 06484674 EFIS: 0623000083 COOP: 061794 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-- |
| Award Date | 10/03/2024 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 2 (Verified on 03/28/2025) |
Sample Information
| Sample Taken Date | 03/24/2025 | Sample Unique Key | 124 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/24/2025 |
| Sample type | Quality Control | A brief description of the sample | CIP aggregates |
| The quantity of what the sample constitutes | 1 per batch | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Rickey | Last name of sampler or witnessed by | Guevara |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Golden Empire - Bakersfield | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-15-0041 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | stockpile or belt cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | NCT09013 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-03-24-124
DIME Test ID: 2025-03-24-124-2
Testing Lab: Sequoia Consultants
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-10-14
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Jonathan Casanova
Date of test: 03/25/2025
Temperature correction: 0
Temperature of solution: 77
Clay reading (test 1): 5.7
Sand reading (test 1): 4.3
Clay reading (test 2): 5.2
Sand reading (test 2): 4.1
Sand equivalent (test 1): 76
Sand equivalent (test 2): 79
Sand equivalent before temperature correction: 78
Sand equivalent after temperature correction: 78
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2025 ✔