Summary for Test 2017-11-29-16-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 11/29/2017 | Sample Unique Key | 16 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/04/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 MG Rocap Assembiy |
| The quantity of what the sample constitutes | 15 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Reyes |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | St Louis Screw Bolt | Transportation Laboratory (TL) Number | C970818 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B30113717 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0093330, TT0093331, TT0093332 |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 24264-6214161303 | |
| Washer Mfg. Lot Number(s) | D3436 | Bolt Specification | A325 |
| Bolt Length(s) | 2.250, 2.500, 2.750 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | B695 |
| Diameter/Size | .875 | Bolt Mfg. Lot Number | BM0500, BM0501, BM0543 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-11-29-16
DIME Test ID: 2017-11-29-16-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-12-14
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 12/06/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3B | B30113717 | 7/8\" | 68876 | 306.4 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 12/7/2017 ✔