Summary for Test 2024-10-02-140-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 994321
DEA: 040K1604
EFIS: 0416000044
DIST-CO-RTE-PM04-ALA,CC-80-R7.6/8.0,0.0/13.5
Award Date02/08/2023
Closeout Date09/14/2026
Work DescriptionCONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER.
Location DescriptionALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date10/02/2024 Sample Unique Key140
Date that the sample was received by the laboratory/organization performing the testing10/02/2024 Sample typeQuality Assurance
A brief description of the sampleClass 2 AB The quantity of what the sample constitutes3 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byIGNACIO
Last name of sampler or witnessed byARECHIGA Title of samplerLab Technician
Telephone number of sampler5102077252 Laboratory sample identificationRich_24_461
Linked DIME Sample ID The fabricator/manufacturer/facility nameClass 2 Aggregate Base from jobsite
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sampleVulcan Vallejo
The plant number A detailed description of where the material sample was collectedtest locations
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number Class 2 AB

Test Details

DIME Sample ID: 2024-10-02-140
DIME Test ID: 2024-10-02-140-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-10-10

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 10/02/2025
Sum of Count or Density: 92703 g/cc
Average of Count or Density: 30901 g/cc
Sum of Moisture Count: 6180 g/cc
Average of Moisture Count: 2060 g/cc
Count Ratio Density: 2.08
Count Ratio Moisture: 2.23
Calculated Percent Relative Compaction: 93.2 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters): Post 01940

Test was verified on 10/10/2025 ✔