Summary for Test 2024-10-02-137-2
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 994321 DEA: 040K1604 EFIS: 0416000044 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,CC-80-R7.6/8.0,0.0/13.5 |
| Award Date | 02/08/2023 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER. |
| Location Description | ALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET |
| QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
| Sample Taken Date | 10/02/2024 | Sample Unique Key | 137 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Class 2 AB |
| The quantity of what the sample constitutes | 3 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
| Title of sampler | Lab Technician | Telephone number of sampler | 5102077252 |
| Laboratory sample identification | Rich_24_459 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Class 2 Aggregate Base from jobsite | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-48-0002 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | Vulcan Vallejo | |
| The plant number | A detailed description of where the material sample was collected | test locations | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | Virgen Class 2 AB |
Test Details
DIME Sample ID: 2024-10-02-137
DIME Test ID: 2024-10-02-137-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-10-10
Test Results
Method Type:: Standard Count
Number of Tests:: 1
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 10/02/2025
Sum of Count or Density: 82293 g/cc
Average of Count or Density: 27431 g/cc
Sum of Moisture Count: 6474 g/cc
Average of Moisture Count: 2158 g/cc
Count Ratio Density: 2.17
Count Ratio Moisture: 2.23
Calculated Percent Relative Compaction: 97.3 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters): Post ID 01944
Test was verified on 10/10/2025 ✔