Summary for Test 2025-09-17-65-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 1000852
DEA: 112N1974
EFIS: 1123000094
DIST-CO-RTE-PM11-IMP-111-23.5/32.1
Award Date04/16/2025
Closeout DateNot set
Work DescriptionCOLD PLANE, HMA-A, RHMA-G, MICROSURFACING, & PAVEMENT MARKINGS.
Location DescriptionIMPERIAL COUNTY NEAR BRAWLEY AND CALIPATRIA AT VARIOUS LOCATIONS FROM 0.2 MILE SOUTH OF ROUTE 78 TO 0.4 MILE SOUTH OF ROUTE 115
QA Service Level1 (Verified on 05/02/2025)

Sample Information

Sample Taken Date09/17/2025 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/19/2025
Sample typeVerification A brief description of the sampleJMFR
The quantity of what the sample constitutes12 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byMasud
Title of samplerTET Telephone number of sampler6199021073
Laboratory sample identification25-09-17-65-JMFR Linked DIME Sample ID2025-09-17-66
The fabricator/manufacturer/facility nameAPI Gateway Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number1 API Val
Binder content (%)7.5 Virgin binder PG PG 70-10
Design binder PG PG 70-10 Binder SupplierValero
RAP content (%)0 WMA AdditivesNo
Antistrip typeLime

Test Details

DIME Sample ID: 2025-09-17-65
DIME Test ID: 2025-09-17-65-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-10-15

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 10/08/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 1552.6 grams
Mass of container filled with the sample and water for Sample 1: 8380.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.398
Theoretical maximum density at 25°C (77°F): 149.3 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Complies Target 2.419 Tested 2.398

Test was verified on 10/15/2025