Summary for Test 2025-09-16-78-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-5.0/10.2 |
| Award Date | 06/17/2024 |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS |
| Location Description | BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32 |
| QA Service Level | 1 (Verified on 04/18/2024) |
Sample Information
| Sample Taken Date | 09/16/2025 | Sample Unique Key | 78 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/18/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Daily 25-178 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | KRC - Orland | Transportation Laboratory (TL) Number | C955794 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 3 | HMA Mix Number | O22451004 |
| Binder content (%) | 7.9 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | |
| RAP content (%) | 0 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-16-78
DIME Test ID: 2025-09-16-78-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-10-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 10/08/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1695.6 g
Mass Loss: 144.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.76 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 7.76 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 7.9%
Test was verified on 10/8/2025 ✔