Summary for Test 2025-09-16-78-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-5.0/10.2 |
| Award Date | 06/17/2024 |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS |
| Location Description | BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32 |
| QA Service Level | 1 (Verified on 04/18/2024) |
Sample Information
| Sample Taken Date | 09/16/2025 | Sample Unique Key | 78 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2" RHMA-G | The quantity of what the sample constitutes | 2 Boxes |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | McKeehan | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | Daily 25-178 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | KRC - Orland | |
| Transportation Laboratory (TL) Number | C955794 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 3 | HMA Mix Number | O22451004 |
| Binder content (%) | 7.9 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | |
| RAP content (%) | 0 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-16-78
DIME Test ID: 2025-09-16-78-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-10-08
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 10/08/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7402.6 grams
Mass of oven-dry sample in air for Sample 1: 1635.8 grams
Mass of container filled with the sample and water for Sample 1: 8367.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.437
Theoretical maximum density at 25°C (77°F): 2430 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2025 ✔