Summary for Test 2017-11-30-5-19
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 212854 DEA: 07342101 EFIS: 0717000244 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-27.0/66.5 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Establish standard vertical clearance. |
| Location Description | In Los Angeles County, at various locations. |
| QA Service Level | 1 (Verified on 10/30/2017) |
Sample Information
| Sample Taken Date | 11/30/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/30/2017 | Sample type | Quality Assurance |
| A brief description of the sample | A325 3/4 Bolt Assembly | The quantity of what the sample constitutes | 7 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Tory |
| Last name of sampler or witnessed by | McLaurin | Title of sampler | QA Inspector |
| Telephone number of sampler | 6616185971 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Cordova Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-279-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
|---|---|---|---|
| Heat Number(s) | 11431677, 131743, DL13102379, 31727470 | Nut Mfg. Lot Number(s) | 331329B |
| Washer Mfg. Lot Number(s) | 0917-617, 343Z13 | Bolt Specification | A325 |
| Bolt Length(s) | 2-3/4 | Nut Specification | A563 DH |
| Washer Specification | F436, F959 | Finish | Mechanically Galvanized |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 150700A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-11-30-5
DIME Test ID: 2017-11-30-5-19
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-12-12
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 12/05/2017
Sample No.: 2B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 343Z13
Finish Coating: ASTM B695 - Mech Galv
Product Markings: 325 Z13
Size: .75 in
Bolt Length: no data
Measurement Average: 3.31 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2017 ✔