Summary for Test 2025-10-03-35-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000176 DEA: 034H76U4 EFIS: 0323000040 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-5.0/10.2 |
| Award Date | 06/17/2024 |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT, INSTALL SIGNAL, LIGHTING, DRAINAGE, & ADA RAMPS |
| Location Description | BUTTE COUNTY IN CHICO FROM MUIR AVENUE TO INTERCHANGE OF STATE ROUTES 99 AND 32 |
| QA Service Level | 1 (Verified on 04/18/2024) |
Sample Information
| Sample Taken Date | 10/03/2025 | Sample Unique Key | 35 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/06/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2" RHMA-O | The quantity of what the sample constitutes | 1 Box |
| From where was the sample collected | Source | First name of sampler or witnessed by | M. |
| Last name of sampler or witnessed by | Atterberry | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | Daily 25-207 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | KRC - Orland | |
| Transportation Laboratory (TL) Number | C803780 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 3 | HMA Mix Number | OR22251004 |
| Binder content (%) | 7.4 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | PNW |
| RAP content (%) | Not set | WMA Additives | Yes |
| Antistrip type |
Test Details
DIME Sample ID: 2025-10-03-35
DIME Test ID: 2025-10-03-35-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-10-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 10/07/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1628.7 g
Mass Loss: 131.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.90 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.16 %
General comments (publicly viewable) (Max 1000 characters): R1
OBC 7.4%
Test was verified on 10/8/2025 ✔