Summary for Test 2017-10-24-13-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 211070 DEA: 080Q3004 EFIS: 0800020191 |
---|---|
DIST-CO-RTE-PM | 08-SBD-138-R17.1/R19.2 |
Award Date | 04/18/2016 |
Closeout Date | 09/28/2020 |
Work Description | REALIGN SECTION OF STATE ROUTE 138 |
Location Description | Near Hesperia from 1.9 mi East of Route 15 to 0.1 mi West of Summit Post Office Road to realign sections of State Route 138 |
QA Service Level | 1 (Verified on 04/27/2016) |
Sample Information
Sample Taken Date | 10/24/2017 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2017 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylindes |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | EDDY | Last name of sampler or witnessed by | SCOTT |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 955-3 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Robertsons Lucerne Valley | Transportation Laboratory (TL) Number | 2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | MINER SHACK DECK POUR |
Structure name | miners shack deck pour |
Material Information
Material Type | Concrete | The concrete mix design number | RRM16065 |
---|---|---|---|
The truck number from where the sample was collected | 1211 | The batch plant ticket number from where the sample was collected | 2872757 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | PLANT |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | MINER SHACK DECK POUR |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-10-24-13
DIME Test ID: 2017-10-24-13-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-12-05
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/05/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 163400 lb
Maximum load on cylinder 2: 160320 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 42 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5759.6 psi
Compressive strength of cylinder 2: 5671.0 psi
Compressive strength (to nearest 10 psi): 5720 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2017 ✔