Summary for Test 2025-09-23-62-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 1000402
DEA: 11430384
EFIS: 1118000114
DIST-CO-RTE-PM11-SD-805-23.7/28.5
Award Date10/09/2024
Closeout DateNot set
Work DescriptionREPLACE DRAINAGE, CONCRETE PAVEMENT, AND MODIFY ELECTRICAL SYSTEMS.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.1 MILE NORTH OF ROUTE 805/52 SEPARATION TO ROUTE 5/805 SEPARATION
QA Service Level1 (Verified on 11/18/2024)

Sample Information

Sample Taken Date09/23/2025 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/25/2025
Sample typePer Request A brief description of the samplePlant Sample
The quantity of what the sample constitutes2 bags From where was the sample collectedSupplier
First name of sampler or witnessed byMohammed Last name of sampler or witnessed byMasud
Title of samplerTET Telephone number of sampler
Laboratory sample identification25-09-23-62-A Linked DIME Sample ID2025-09-23-61
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-31-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number21218180AH MM

Test Details

DIME Sample ID: 2025-09-23-62
DIME Test ID: 2025-09-23-62-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2025-10-16

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 10/06/2025
Clay Level (Test 1): 5
Sand Level (Test 1): 3.8
Clay Level (Test 2): 4.7
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5.1
Sand Level (Test 3): 3.9
Sand Equivalent (Test 1): 76
Sand Equivalent (Test 2): 83
Sand Equivalent (Test 3): 77
Sand Equivalent: 79
General comments (publicly viewable) (Max 1000 characters): Complies

Test was verified on 10/16/2025