Summary for Test 2025-07-11-64-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214669
DEA: 07325504
EFIS: 0716000085
DIST-CO-RTE-PM07-LA-605-
Award DateNot set
Closeout DateNot set
Work DescriptionSlab Replacement and Shoulder Resurfacing
Location DescriptionNot set
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date07/11/2025 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2025
Sample typeAcceptance A brief description of the sample3/4" RHMA type g sp pg64-16
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byGerado Last name of sampler or witnessed byZubieta
Title of samplerTEC Telephone number of sampler
Laboratory sample identification25-469 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number106835
Binder content (%)7.4 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder Supplier
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2025-07-11-64
DIME Test ID: 2025-07-11-64-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-10-06

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 08/01/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4082.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6149.9 g
Mass of HMA Sample prior to ignition: 2067.8 g
Mass Loss: 160.3 g
Mass of aggregate remaining after ignition: 1907.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.31 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 7.44 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/6/2025