Summary for Test 2025-09-09-69-3
Test performed: ASTM D5329-20Project Information
| Project Identifiers | Project ID: 1000963 DEA: 09398504 EFIS: 0924000059 |
|---|---|
| DIST-CO-RTE-PM | 09-MNO-395-R44.6/50.7 |
| Award Date | 04/10/2025 |
| Closeout Date | 10/31/2025 |
| Work Description | ASPHALTIC EMULSION (FOG SEAL COAT) & PRECOATED AGGREGATE (SEAL COAT). |
| Location Description | MONO COUNTY NEAR LEE VINING FROM 0.3 MILE SOUTH OF OLD WEST PORTAL ROAD TO 0.2 MILE SOUTH OF UTILITY ROAD |
| QA Service Level | 1 (Verified on 04/09/2025) |
Sample Information
| Sample Taken Date | 09/09/2025 | Sample Unique Key | 69 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2025 |
| Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
| The quantity of what the sample constitutes | 1can | From where was the sample collected | Source |
| First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Wengel |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | ASPHALT RUBBER BINDER | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2025-09-09-69
DIME Test ID: 2025-09-09-69-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2025-10-08
Test Results
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 10/02/2025
Temperature: 25 C
Ball Penetration (P1): 6 mm
Final Dial reading (F1): 76 mm
Ball Penetration (P2): 5 mm
Final Dial reading (F2): 74 mm
Ball Penetration (P3): 5 mm
Final Dial reading (F3): 73 mm
Resilience 1: 30 %
Resilience 2: 31 %
Resilience 3: 32 %
Average Resilience: 31 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2025 ✔