Summary for Test 2025-09-03-62-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/03/2025 | Sample Unique Key | 62 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2025 |
| Sample type | Verification | A brief description of the sample | JMF Verification |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-09-03-62-JMFV | Linked DIME Sample ID | 2025-09-03-63 |
| The fabricator/manufacturer/facility name | Vulcan Escondido | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | 320300 Esc Val | |
| Binder content (%) | 5.3 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 22 | WMA Additives | No |
| Antistrip type | No |
Test Details
DIME Sample ID: 2025-09-03-62
DIME Test ID: 2025-09-03-62-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-10-08
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 10/02/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4028.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5592.7 g
Mass of HMA Sample prior to ignition: 1564.0 g
Mass Loss: 89.0 g
Mass of aggregate remaining after ignition: 1475.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.13 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.56 %
General comments (publicly viewable) (Max 1000 characters): Complies Target 5.30%, Tested 5.56 % Saved material for T30
Test was verified on 10/8/2025 ✔