Summary for Test 2025-08-14-72-6

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000996
DEA: 101S6404
EFIS: 1024000105
DIST-CO-RTE-PM10-MER-165-L0.0/7.0,8.7/16.5
Award Date05/13/2025
Closeout DateNot set
Work DescriptionRESURFACE PAVEMENT WITH RHMA AND HMA.
Location DescriptionMERCED COUNTY IN AND NEAR LOS BANOS FROM 0.3 MILE SOUTH OF POLE LINE ROAD TO 0.2 MILE SOUTH OF MASON ROAD AND FROM 0.1 MILE SOUTH OF CANAL FARM LANE TO 1.4 MILES NORTH OF WOLFSEN ROAD
QA Service Level1 (Verified on 04/18/2025)

Sample Information

Sample Taken Date08/14/2025 Sample Unique Key72
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/20/2025
Sample typeQuality Assurance A brief description of the sample3/4 WMA-SP
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byM Last name of sampler or witnessed bySingh
Title of samplerTransportation Engineer Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSanta Fe Aggregate Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form0600008 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA SupplierTeichert- Santa Fe Aggregates
Certified Asphalt SupplierAlbina Asphalt - Chowchilla CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-08-14-72
DIME Test ID: 2025-08-14-72-6
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-10-03

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas
Date of test: 09/26/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 206.826 grams
Mass of container #2 before test (m2i): 205.404 grams
Mass of container #1 after test (m1f): 206.754 grams
Mass of container #2 after test (m2f): 205.322 grams
Mass of empty container #1: 172.128 grams
Mass of empty container #2: 170.386 grams
Mass correction factor: 0.030
Average mass change: -0.191 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change

Test was verified on 10/3/2025