Summary for Test 2025-08-14-72-1

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 1000996
DEA: 101S6404
EFIS: 1024000105
DIST-CO-RTE-PM10-MER-165-L0.0/7.0,8.7/16.5
Award Date05/13/2025
Closeout Date06/02/2026
Work DescriptionRESURFACE PAVEMENT WITH RHMA AND HMA.
Location DescriptionMERCED COUNTY IN AND NEAR LOS BANOS FROM 0.3 MILE SOUTH OF POLE LINE ROAD TO 0.2 MILE SOUTH OF MASON ROAD AND FROM 0.1 MILE SOUTH OF CANAL FARM LANE TO 1.4 MILES NORTH OF WOLFSEN ROAD
QA Service Level1 (Verified on 04/18/2025)

Sample Information

Sample Taken Date08/14/2025 Sample Unique Key72
Date that the sample was received by the laboratory/organization performing the testing08/20/2025 Sample typeQuality Assurance
A brief description of the sample3/4 WMA-SP The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byM
Last name of sampler or witnessed bySingh Title of samplerTransportation Engineer
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSanta Fe Aggregate
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form0600008
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA SupplierTeichert- Santa Fe Aggregates
Certified Asphalt SupplierAlbina Asphalt - Chowchilla CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-08-14-72
DIME Test ID: 2025-08-14-72-1
Testing Lab: Atlas - Denver
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-10-03

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Atlas
Date of test: 09/19/2025
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.172 kPa
Phase Angle (δ) (for the 10 cycles): 84.0 degree
Complex Modulus (G*) (for the 10 measurements): 1.425 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.43 kPa
General comments (publicly viewable) (Max 1000 characters): Original

Test was verified on 10/3/2025 ✔