Summary for Test 2025-09-04-64-4
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1001213 DEA: 11431644 EFIS: 1122000232 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-78-N17.7 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Cold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical. |
| Location Description | IN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING. |
| QA Service Level | 1 (Verified on 05/07/2025) |
Sample Information
| Sample Taken Date | 09/04/2025 | Sample Unique Key | 64 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/05/2025 |
| Sample type | Per Request | A brief description of the sample | Plant Sample |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Mohammed | Last name of sampler or witnessed by | Masud |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 2025-09-4-64-S | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cemex Escondido | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 1610838 | Lot number | |
| Sublot number | Aggregate Mix Number |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2025-10-1: PCC Aggregates (Size 1"): Bridges and Major Structures - Sieve Analysis | 3 | 2025-09-04-64-4 |
Test Details
DIME Sample ID: 2025-09-04-64
DIME Test ID: 2025-09-04-64-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-10-03
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Gerardo Cordero
Date of test: 10/02/2025
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 516 grams | ||||||
| 0.0 grams | 100 % | |||||
| 3.0 grams | 99 % | |||||
| 73.0 grams | 86 % | |||||
| 209.0 grams | 59 % | |||||
| 332.0 grams | 36 % | |||||
| 433.0 grams | 16 % | |||||
| 487.0 grams | 6 % | |||||
| 511.0 grams | 1 % | |||||
| 513.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters): COMPLIANCE
Test was verified on 10/3/2025 ✔