Summary for Test 2025-09-19-43-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1000435 DEA: 030J01U4 EFIS: 0323000244 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-28-0.1/11.0 |
| Award Date | 10/02/2024 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), COLD PLANE AC PVMT, RDWY EXC, & CL 2 AB. |
| Location Description | PLACER COUNTY FROM 0.1 MILE EAST OF ROUTE 89 AT TAHOE CITY TO THE NEVADA STATE LINE AT KINGS BEACH |
| QA Service Level | 1 (Verified on 07/30/2024) |
Sample Information
| Sample Taken Date | 09/19/2025 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA w/ 15% RAP |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Dustan | Last name of sampler or witnessed by | Kliethermes |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Daily 25-188 | Linked DIME Sample ID | 2025-09-19-29 |
| The fabricator/manufacturer/facility name | Teichert Martis | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 4 | HMA Mix Number | 30540732407P |
| Binder content (%) | 5.0 | Virgin binder PG | |
| Design binder PG | PG 64-28 | Binder Supplier | PNW |
| RAP content (%) | 15 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-19-43
DIME Test ID: 2025-09-19-43-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-10-02
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Joshua Wilson
Date of test: 10/01/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7402.6 grams
Mass of oven-dry sample in air for Sample 1: 2618.1 grams
Mass of container filled with the sample and water for Sample 1: 8969.0 grams
Temperature of Water: 0 °F
Specific Gravity for Sample 1: 2.489
Theoretical maximum density at 25°C (77°F): 2482 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/2/2025 ✔