Summary for Test 2025-09-17-45-2
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 1000665 DEA: 081K4004 EFIS: 0819000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-15-3.5/6.8 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC). |
| Location Description | TEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 09/17/2025 | Sample Unique Key | 45 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/18/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 4x8 |
| The quantity of what the sample constitutes | 9 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Luis | Last name of sampler or witnessed by | Maldanado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 1079-917CL | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cemex / Orca | Transportation Laboratory (TL) Number | 1079-917CL |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | n/p |
|---|---|---|---|
| The truck number from where the sample was collected | 10070467 | The batch plant ticket number from where the sample was collected | NA |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | COLUMN REPAIR WRAP, BENT 3 COLUMN 1-2 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-09-17-45
DIME Test ID: 2025-09-17-45-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-10-01
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 10/01/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 71650 lb
Maximum load on cylinder 2: 72210 lb
Maximum load on cylinder 3: 73450 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 14 days
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 5673.0 psi
Compressive strength of cylinder 2: 5744.6 psi
Compressive strength of cylinder 3: 5815.5 psi
Compressive strength (to nearest 10 psi): 5740 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2025 ✔