Summary for Test 2025-08-29-9-1
Test performed: AASHTO T315-24Project Information
| Project Identifiers | Project ID: 994751 DEA: 010C5004 EFIS: 0112000292 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-36-11.3/34.6 |
| Award Date | 03/02/2023 |
| Closeout Date | Not set |
| Work Description | Project Name: Bridge Rail Replacement - 3 Bridges |
| Location Description | Hely Creek, Little Larabee Creek and Butte Creek Bridge. |
| QA Service Level | 1 (Verified on 04/27/2023) |
Sample Information
| Sample Taken Date | 08/29/2025 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2025 |
| Sample type | Quality Assurance | A brief description of the sample | PG 64-16 binder |
| The quantity of what the sample constitutes | 1 can of binder | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jack | Last name of sampler or witnessed by | Naylor |
| Title of sampler | Inspector | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fracer Fortuna Plant A | Transportation Laboratory (TL) Number | 00000 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2025-08-29-9
DIME Test ID: 2025-08-29-9-1
Testing Lab: Atlas - Denver
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2025-10-03
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Atlas
Date of test: 09/22/2025
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.141 kPa
Phase Angle (δ) (for the 10 cycles): 87.3 degree
Complex Modulus (G*) (for the 10 measurements): 1.172 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.17 kPa
General comments (publicly viewable) (Max 1000 characters): Original
Test was verified on 10/3/2025 ✔