Summary for Test 2025-06-11-116-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 995494 DEA: 081K4904 EFIS: 0819000050 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R105.1/R105.9 |
| Award Date | 05/28/2024 |
| Closeout Date | Not set |
| Work Description | BUILDING WORK, HMA, AND TEMPORARY PORTABLE SANITARY FACILITIES. |
| Location Description | SAN BERNARDINO COUNTY ABOUT 36 MILES WEST OF NEEDLES FROM 2.1 MILES TO 1.3 MILES WEST OF GOFFS ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 01/18/2024) |
Sample Information
| Sample Taken Date | 06/11/2025 | Sample Unique Key | 116 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2025 |
| Sample type | Quality Control | A brief description of the sample | structural concrete |
| The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Adrian | Last name of sampler or witnessed by | Plentywounds |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HI-GRADE MATERIALS | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT752F25 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 34003458 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | WB Comfort Station B | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-06-11-116
DIME Test ID: 2025-06-11-116-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-10-01
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: John Romero
Date of test: 07/09/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 138990 lb
Maximum load on cylinder 2: 139640 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4930 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/1/2025 ✔