Summary for Test 2025-09-19-38-1
Test performed: CTM 643-April 2020Project Information
| Project Identifiers | Project ID: 1000130 DEA: 021J3504 EFIS: 0220000061 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-29-41.1/55.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Diddy Roost Culverts - Drainage System Restoration |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/24/2024) |
Sample Information
| Sample Taken Date | 09/19/2025 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2025 |
| Sample type | Preliminary | A brief description of the sample | Sand, Silt, Rock and Soil |
| The quantity of what the sample constitutes | Not Provided | From where was the sample collected | Source |
| First name of sampler or witnessed by | Derek | Last name of sampler or witnessed by | Serna |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D80053 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Roadside | Transportation Laboratory (TL) Number | 897610 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | C-8 |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Shoulder at Inlet SHA, 299 PM. 49.63 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-09-19-38
DIME Test ID: 2025-09-19-38-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2025-09-30
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 09/29/2025
Minimum soil resistance of the lab measurement: 7100 Ohms
Soil sample temperature: 21.9 C
Soil box constant: 1
pH of soil: 7.10
Minimum soil resistance corrected to 15.5: 8236 Ohm-cm
Minimum soil resistivity at 15.5: 8236 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=7.10, p=8236.Ω∙cm
Test was verified on 9/30/2025 ✔