Summary for Test 2025-09-16-41-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994875 DEA: 101F1804 EFIS: 1016000077 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-4-R16.0/R19.4 |
| Award Date | 09/20/2023 |
| Closeout Date | Not set |
| Work Description | BRIDGE WORK, CONCRETE BARRIER, AND INSTALL RAMP METER SYSTEM. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.3 MILE EAST OF ROUTE 4/5 SEPARATION TO 0.4 MILE WEST OF ROUTE 4/99 SEPARATION |
| QA Service Level | 1 (Verified on 06/14/2023) |
Sample Information
| Sample Taken Date | 09/16/2025 | Sample Unique Key | 41 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2025 | Sample type | Quality Assurance |
| A brief description of the sample | Lenton A2 Coupler | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | NA |
| Last name of sampler or witnessed by | NA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Field | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | Lenton | Intermediate Assembler or Fabricator | |
| Rebar Size | #8 | Coupler Model | Lenton A2 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | A1512 | Rebar Heat Number(s) | 9008625 |
| Rebar Size 2 | Coupler Unique ID | ST-17-01 |
Test Details
DIME Sample ID: 2025-09-16-41
DIME Test ID: 2025-09-16-41-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2025-09-29
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/29/2025
UTM: NA
Halo ID: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 9008625 | 1 | 0.79 | 0.0022 | 76180 | 96430 | NA | Miguel Baltazar |
| 2 | 2 | 9008625 | 1 | 0.79 | 0 | 76150 | 96392 | NA | Miguel Baltazar |
| 3 | 3 | 9008625 | 1 | 0.79 | 0 | 75840 | 96000 | NA | Miguel Baltazar |
| 4 | 4 | 9008625 | 1 | 0.79 | 0 | 76530 | 96873 | NA | Miguel Baltazar |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/29/2025 ✔