Summary for Test 2025-08-26-45-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000575
DEA: 11430904
EFIS: 1119000199
DIST-CO-RTE-PM11-SD-5,805-Var
Award Date02/12/2025
Closeout DateNot set
Work DescriptionRESURFACE BRIDGE, REPLACE BRIDGE BARRIER, MGS, AND MODIFY ELECT.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/04/2025)

Sample Information

Sample Taken Date08/26/2025 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing08/27/2025 Sample typeQuality Control
A brief description of the samplesc The quantity of what the sample constitutescy
From where was the sample collectedSource First name of sampler or witnessed byLouis
Last name of sampler or witnessed byRiley Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namerobertsons readt mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure namebridge deck
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM20038
The truck number from where the sample was collected1939 The batch plant ticket number from where the sample was collected1562866
Concrete batch plantOtay Mesa The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedNB Rte805, Bridge Deck Where the material sample would have been placed if not sampledNB Rte805, Bridge Deck
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-08-26-45
DIME Test ID: 2025-08-26-45-2
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-09-26

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Jesse Lara
Date of test: 09/23/2025
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Average cylinder density (to nearest 1 pcf): 145.7 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Avg Compressive Strength - 4710psi

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
24-3357 Concrete 2025-08-26 SC RRM20038pdf231.64 KB09/26/20252025-08-26-45-2   Info

Test was verified on 9/26/2025 ✔