Summary for Test 2025-09-03-62-7

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/03/2025 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2025
Sample typeVerification A brief description of the sampleJMF Verification
The quantity of what the sample constitutes12 boxes From where was the sample collectedSupplier
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of samplerTET Telephone number of sampler6199366795
Laboratory sample identification25-09-03-62-JMFV Linked DIME Sample ID2025-09-03-63
The fabricator/manufacturer/facility nameVulcan Escondido Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number320300 Esc Val
Binder content (%)5.3 Virgin binder PGPG 58-22
Design binder PG PG 64-16 Binder SupplierValero
RAP content (%)22 WMA AdditivesNo
Antistrip typeNo

Test Details

DIME Sample ID: 2025-09-03-62
DIME Test ID: 2025-09-03-62-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-09-26

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 09/26/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3986.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5641.4 g
Mass of HMA Sample prior to ignition: 1654.5 g
Mass Loss: 98.8 g
Mass of aggregate remaining after ignition: 1555.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.97 %
General comments (publicly viewable) (Max 1000 characters): 3 RAP burns

Test was verified on 9/26/2025