Summary for Test 2025-08-11-67-7
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000538 DEA: 042Q6104 EFIS: 0419000030 |
|---|---|
| DIST-CO-RTE-PM | 04-NAP-29-R7.3/13.5 |
| Award Date | 11/04/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE, RHMA OVERLAY, INSTALL MGS, CURB RAMP, AND RUMBLE STRIP. |
| Location Description | NAPA COUNTY IN AND NEAR NAPA FROM 0.2 MILE NORTH OF NAPA RIVER BRIDGE OVERHEAD TO 0.1 MILE SOUTH OF SIERRA AVENUE. |
| QA Service Level | 1 (Verified on 08/29/2024) |
Sample Information
| Sample Taken Date | 08/11/2025 | Sample Unique Key | 67 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/11/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2 RHMA-G | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Christian |
| Last name of sampler or witnessed by | Sousa | Title of sampler | |
| Telephone number of sampler | 5306513393 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Lake Herman Drum Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 2 |
| Sublot number | 5 | HMA Mix Number | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-08-11-67
DIME Test ID: 2025-08-11-67-7
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-09-26
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Conception
Date of test: 08/18/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1671.7 g
Mass Loss: 172.3 g
Correction Factor (Percent by mass of HMA Specimen): 1.54 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 8.59 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/26/2025 ✔