Summary for Test 2025-09-18-57-6
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 1000994 DEA: 070Y1804 EFIS: 0724000139 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-60-0.0/R3.3 |
| Award Date | 04/28/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE ASPHALT CONCRETE SURFACING AND SLURRY SEAL. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM JUNCTION ROUTE 10 TO ROUTE 60/710 SEPARATION |
| QA Service Level | 1 (Verified on 07/09/2025) |
Sample Information
| Sample Taken Date | 09/18/2025 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2025 |
| Sample type | Verification | A brief description of the sample | EMULSION |
| The quantity of what the sample constitutes | 2qt, one container | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ricardo | Last name of sampler or witnessed by | Richard QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Substanable Emuision | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | QS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | N/A |
Test Details
DIME Sample ID: 2025-09-18-57
DIME Test ID: 2025-09-18-57-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Particle Charge Cationic Emulsified (Sec. 8))
Test Release Date: 2025-09-29
Test Results
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/22/2025
Level of current used: 8.0 mA
Electrode Type: Positive
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/29/2025 ✔