Summary for Test 2025-09-26-5-1

Test performed: ASTM C138-17a

Project Information

Project IdentifiersProject ID: 1001028
DEA: 07317804
EFIS: 0715000274
COOP: 075065
DIST-CO-RTE-PM07-VEN-34-6.3
Award Date10/29/2024
Closeout DateNot set
Work DescriptionConstruct grade separation structure and connector ramps
Location DescriptionSR34 and Rice Avenue, Oxnard
QA Service Level2 (Verified on 02/25/2025)

Sample Information

Sample Taken Date09/26/2025 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/26/2025
Sample typeQuality Control A brief description of the sampleT-II/V Cement
The quantity of what the sample constitutes31.29 CY From where was the sample collectedFabricator
First name of sampler or witnessed byBenjamin Last name of sampler or witnessed byAragon
Title of samplerQC Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC - Shafter Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameRice Avenue OH Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSCC-S8.5-0FG
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected6549
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from wheelbarrow collected from chute of ready mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-09-26-5
DIME Test ID: 2025-09-26-5-1
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Test Release Date: 2025-09-26

Test Results


Input Type: Calculated
Tester's full name: Adrian Estrada
Date of test: 09/26/2025
Identification of concrete represented by the sample: CAWF 60 inch Girder
Volume of the measure: 0.250 ft^3
Density of concrete: 154.9 lb/ft^3
Yield of concrete: no data
Relative yield of the batch: no data
Cement content: no data
Air content: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/26/2025