Summary for Test 2025-09-08-33-4

Test performed: ASTM D638-Dec14

Project Information

Project IdentifiersProject ID: 1001124
DEA: 070W9704
EFIS: 0723000187
DIST-CO-RTE-PM07-LA-10,60,71-Var
Award Date06/02/2025
Closeout DateNot set
Work DescriptionMETHACRYLATE, POLYESTER OVERLAY, JOINT SEAL REPAIR, AND SPALL REPAIR.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/06/2025)

Sample Information

Sample Taken Date09/08/2025 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/09/2025
Sample typeQuality Control A brief description of the sample1 gallon can / PPC 1121 RESIN
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000183KBP Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ5H01114
Batch numberAZ5H01114 Mix numberAZ5H01114

Test Details

DIME Sample ID: 2025-09-08-33
DIME Test ID: 2025-09-08-33-4
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2025-09-23

Test Results


Number of specimens tested: 6
Input Type: Measured
Tester's full name: Laura Bird
Date of test: 09/11/2025
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.483 in
Sample 1 Thickness: 0.251 in
Sample 1 Area: 0.1212 in^2
Sample 1 Ultimate Strength Actual: 384 lbs
Sample 1 percent elongation: 75.4 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.483 in
Sample 2 Thickness: 0.259 in
Sample 2 Area: 0.1251 in^2
Sample 2 Ultimate Strength Actual: 344 lbs
Sample 2 percent elongation: 61.9 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.484 in
Sample 3 Thickness: 0.252 in
Sample 3 Area: 0.122 in^2
Sample 3 Ultimate Strength Actual: 406 lbs
Sample 3 percent elongation: 79.6 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.484 in
Sample 4 Thickness: 0.249 in
Sample 4 Area: 0.1205 in^2
Sample 4 Ultimate Strength Actual: 375 lbs
Sample 4 percent elongation: 73.8 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.483 in
Sample 5 Thickness: 0.256 in
Sample 5 Area: 0.1236 in^2
Sample 5 Ultimate Strength Actual: 390 lbs
Sample 5 percent elongation: 74.8 %
Sample 5 Time: 0 MM:SS
Sample 6 Width: 0.483 in
Sample 6 Thickness: 0.252 in
Sample 6 Area: 0.1217 in^2
Sample 6 Ultimate Strength Actual: 369 lbs
Sample 6 percent elongation: 71.7 %
Sample 6 Time: 0 MM:SS
Sample 1 Ultimate strength: 3168.3 psi
Sample 2 Ultimate strength : 2749.8 psi
Sample 3 Ultimate strength: 3327.9 psi
Sample 4 Ultimate strength: 3112 psi
Sample 5 Ultimate strength: 3155.3 psi
Sample 6 Ultimate strength : 3032 psi
Ultimate Strength Average: 3091 psi
Percent Elongation Average: 73 %
General comments (publicly viewable) (Max 1000 characters): Accepted supplier's result.

Test was verified on 9/23/2025