Summary for Test 2025-09-11-45-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001227
DEA: 074V5004
EFIS: 0723000160
DIST-CO-RTE-PM07-LA-210-R24.7/R25.3
Award Date06/13/2025
Closeout Date12/02/2025
Work DescriptionOVERLAY AC SHOULDER, REPLACE SHOULDER, AND SLAB REPLACEMENT.
Location DescriptionLOS ANGELES COUNTY IN PASADENA FROM 0.1 MILE EAST OF ORANGE GROVE BOULEVARD OVERCROSSING TO 0.2 MILE WEST OF MARENGO AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/02/2025)

Sample Information

Sample Taken Date09/11/2025 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing09/18/2025 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byDaniel
Last name of sampler or witnessed bySequoia QC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-09-11-45
DIME Test ID: 2025-09-11-45-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-09-24

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 09/22/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.822 grams
Mass of container #2 before test (m2i): 207.869 grams
Mass of container #1 after test (m1f): 203.781 grams
Mass of container #2 after test (m2f): 207.829 grams
Mass of empty container #1: 168.838 grams
Mass of empty container #2: 172.878 grams
Mass correction factor: 0.006
Average mass change: -0.110 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/24/2025 ✔