Summary for Test 2025-08-14-99-1

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/14/2025 Sample Unique Key99
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2025
Sample typeAuthorization A brief description of the sample1-3/8 inch ASTM A722, Grade 150ksi, threaded bar anchorage system with anchor nut, bearing plate with countersunk hole, and coupler
The quantity of what the sample constitutesNA From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDywidag Systems Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar SizeM36
Nut Specification for Threaded BarASTM A897 System ManufacturerDywidag Systems
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)58064503/04
Nut Heat Number(s)H299 Bar Lot Number
Nut Lot Number Coupler Heat Number(s)A222183
Coupler Grade

Test Details

DIME Sample ID: 2025-08-14-99
DIME Test ID: 2025-08-14-99-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2025-10-15

Test Results


Number of Threaded Bar Samples: 6
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/22/2025
UTM: NA
Temperature: 0 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
111 3/858064503041.5815090012300000NAMiguel Baltazar
221 3/858064503041.5815310012340000NAMiguel Baltazar
331 3/858064503041.5815430012330000NAMiguel Baltazar
441 3/858064503041.5815490012340000NAMiguel Baltazar
551 3/858064503041.43153300136500934NAMiguel Baltazar
661 3/858064503041.5815450012330090NAMiguel Baltazar

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/15/2025