Summary for Test 2025-09-16-45-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000665
DEA: 081K4004
EFIS: 0819000031
DIST-CO-RTE-PM08-RIV-15-3.5/6.8
Award Date01/29/2025
Closeout DateNot set
Work DescriptionHMA (TYPE A), RDWY EXC, STR CONC RET WALL, RUBBERIZED HMA (OGFC).
Location DescriptionTEMECULA FROM 0.1 MI NORTH OF TEMECULA PARKWAY TO 0.2 MI NORTH OF WINCHESTER ROAD
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date09/16/2025 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2025
Sample typeVerification A brief description of the sampleJMF verification sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byMCPHERSON
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-09-16-45
DIME Test ID: 2025-09-16-45-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-09-19

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 09/19/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 207.907 grams
Mass of container #2 before test (m2i): 206.489 grams
Mass of container #1 after test (m1f): 207.901 grams
Mass of container #2 after test (m2f): 206.484 grams
Mass of empty container #1: 172.802 grams
Mass of empty container #2: 171.472 grams
Mass correction factor: 0.006
Average mass change: -0.010 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/19/2025