Summary for Test 2025-09-18-16-3

Test performed: AASHTO T30-19

Project Information

Project IdentifiersProject ID: 993798
DEA: 09366804
EFIS: 0916000021
DIST-CO-RTE-PM09-INY-395-117.3/117.9
Award Date04/03/2025
Closeout DateNot set
Work DescriptionMEADOW FARMS ADA
Location DescriptionINYO COUNTY NEAR BISHOP FROM 0.1 MILE EAST OF SEE VEE LANE TO BARLOW LANE
QA Service Level1 (Verified on 08/14/2023)

Sample Information

Sample Taken Date09/18/2025 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2025
Sample typeQuality Assurance A brief description of the sample3/4" Coldfeed & RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byCarapazza
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationCF-01 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite 5 Bridges Plant Bishop Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-14-0001
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample Device at Hot Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-09-18-16
DIME Test ID: 2025-09-18-16-3
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-09-19

Test Results


Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 09/19/2025
Cumulative Mass RetainedCorrection FactorCumulative Percent Passing
1471.0 grams
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams0.0 %100 %
0.0 grams-0.2 %100 %
262.4 grams-7.4 %75 %
551.8 grams-9.9 %53 %
769.4 grams-4.3 %43 %
947.1 grams-4.1 %32 %
1109.8 grams-3.4 %21 %
1226.6 grams-2.5 %14 %
1312.2 grams-1.6 %9.2 %
1331.4 grams
General comments (publicly viewable) (Max 1000 characters): CF-01 RAP

Test was verified on 9/19/2025