Summary for Test 2025-08-21-63-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 994574
DEA: 050C7334
EFIS: 0518000116
DIST-CO-RTE-PM05-SCR-1-10.5/13.4
Award Date06/29/2023
Closeout DateNot set
Work DescriptionCONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING
QA Service Level1 (Verified on 04/13/2023)

Sample Information

Sample Taken Date08/21/2025 Sample Unique Key63
Date that the sample was received by the laboratory/organization performing the testing08/22/2025 Sample typeQuality Control
A brief description of the sample4x8 concrete cylinders The quantity of what the sample constitutes(5) 4x8 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byJohn
Last name of sampler or witnessed byHiner Title of sampler
Telephone number of sampler Laboratory sample identification296399
Linked DIME Sample ID The fabricator/manufacturer/facility nameLas Animas
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameCapitola Ave overcrossing barrier and sidewalk - along eastside- south half
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberC2S30
The truck number from where the sample was collected124 The batch plant ticket number from where the sample was collected394491
Concrete batch plantLas Animas Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-08-21-63
DIME Test ID: 2025-08-21-63-1
Testing Lab: Construction Testing Services
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-09-19

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Mahurin
Date of test: 09/18/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 80760 lb
Maximum load on cylinder 2: 84340 lb
Maximum load on cylinder 3: 85490 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 6640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/19/2025 ✔