Summary for Test 2025-09-15-38-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1001063 DEA: 033G3804 EFIS: 0324000122 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-R23.9/30.8,31.0/31.6 |
| Award Date | 05/27/2025 |
| Closeout Date | Not set |
| Work Description | HMA OVERLAY, COLD PLANE, AND REMOVE & REPLACE PVMT DELINEATION. |
| Location Description | BUTTE COUNTY NEAR CHICO FROM NOPEL AVENUE TO 1.3 MILES WEST OF CARPENTER RIDGE ROAD AND FROM 1.1 MILES WEST OF CARPENTER RIDGE ROAD TO 0.5 MILE WEST OF CARPENTER RIDGE ROAD |
| QA Service Level | 1 (Verified on 03/19/2025) |
Sample Information
| Sample Taken Date | 09/15/2025 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/15/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" HMA w/ 25% RAP |
| The quantity of what the sample constitutes | 2 Boxes | From where was the sample collected | Source |
| First name of sampler or witnessed by | M. | Last name of sampler or witnessed by | Atterberry |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Daily 25-175 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | C803777 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 2 |
| Sublot number | 2 | HMA Mix Number | 30940142416V |
| Binder content (%) | 5.2 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 64-16 | Binder Supplier | Valero |
| RAP content (%) | 25 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-15-38
DIME Test ID: 2025-09-15-38-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-09-18
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 09/17/2025
Specific Gravity for Sample 1: 2.549
Theoretical maximum density at 25°C (77°F): 3 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2025 ✔