Summary for Test 2025-07-29-57-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 1001056
DEA: 112N2074
EFIS: 1123000286
DIST-CO-RTE-PM11-SD-54,805-Var
Award Date05/23/2025
Closeout DateNot set
Work DescriptionGRIND BRIDGE DECKS, POLYESTER CONCRETE OVERLAY, REPAIR APPROACH SLABS.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 05/30/2025)

Sample Information

Sample Taken Date07/29/2025 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2025
Sample typeQuality Control A brief description of the sample2 pints 204, CHP, Z-Cure,8020
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGilberto Last name of sampler or witnessed byGonzalez
Title of samplerQuality Control Manager Telephone number of sampler7076245467
Laboratory sample identification000172KBP Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) Number25-129
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)25-80-451550
Batch number2580451550 Mix number2580451550

Test Details

DIME Sample ID: 2025-07-29-57
DIME Test ID: 2025-07-29-57-1
Testing Lab: Future Labs, LLC
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2025-09-18

Test Results


Input Type: Calculated
Tester's full name: Alex Hamilton
Date of test: 09/10/2025
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9
Volatile content (ASTM D 2369) 30% max: 3.4
Flash point (ASTM D 3828) more than 180 deg F: 212
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 636
Tack free time, 400 minutes max: 240
General comments (publicly viewable) (Max 1000 characters): Accepted CTM 551 based on supplier's result.

Test was verified on 9/18/2025