Summary for Test 2025-09-15-34-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 994901 DEA: 112T3434 EFIS: 1120000081 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-5.1/8.3 |
| Award Date | 01/29/2024 |
| Closeout Date | Not set |
| Work Description | SOUNDWALLS, WIDEN FREEWAY, STRUCTURES, LANDSCAPE AND ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM PALOMAR STREET OVERCROSSING TO 0.5 MILE NORTH OF BONITA ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 03/21/2024) |
Sample Information
| Sample Taken Date | 09/15/2025 | Sample Unique Key | 34 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/15/2025 | Sample type | Quality Control |
| A brief description of the sample | CIP Concrete Aggregate | The quantity of what the sample constitutes | 1 per batch |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Rodrigo |
| Last name of sampler or witnessed by | Lupian | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Associated Ready Mix - Otay | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | belt cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-09-15-34
DIME Test ID: 2025-09-15-34-2
Testing Lab: Sequoia Consultants
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-09-17
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Manuel Mora
Date of test: 09/16/2025
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 4.9
Sand reading (test 1): 4.2
Clay reading (test 2): 5
Sand reading (test 2): 4.2
Sand equivalent (test 1): 86
Sand equivalent (test 2): 84
Sand equivalent before temperature correction: 85
Sand equivalent after temperature correction: 85
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/17/2025 ✔