Summary for Test 2025-08-14-113-2

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 995229
DEA: 07355404
EFIS: 0719000010
DIST-CO-RTE-PM07-LA-2,210-15.0/57.5,R18.7/R19.4
Award Date01/30/2024
Closeout Date01/26/2026
Work DescriptionREPLACE AND INSTALL DRAINAGE SYSTEM, AND PERFORM SLOPE PAVING.
Location DescriptionLOS ANGELES COUNTY ON ROUTE 2 FROM 1.0 MILE NORTH OF CLIFFORD STREET TO MOUNT WATERMAN SKI LIFTS AND ON ROUTE 210 FROM 0.5 MILE EAST OF OCEAN VIEW BOULVEARD OVERCROSSING TO 0.2 MILE EAST OF ALTA CANYADA ROAD OVERCROSSING
QA Service Level1 (Verified on 10/19/2023)

Sample Information

Sample Taken Date08/14/2025 Sample Unique Key113
Date that the sample was received by the laboratory/organization performing the testing08/14/2025 Sample typeQuality Assurance
A brief description of the sampleClass 3 Aggregate Base The quantity of what the sample constitutes1,193 SY
From where was the sample collectedJob Site First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byArroyo Title of samplerMaterials Tester
Telephone number of sampler7605743880 Laboratory sample identification25-2711
Linked DIME Sample ID The fabricator/manufacturer/facility namen/a
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameGore 11 NB 2 FWY
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)n/a
The fabricator's/manufacturer's product name for the sampleClass 3 Aggregate Base The fabricator/manufacturer designation for the sampleCompactions Testing
The plant number A detailed description of where the material sample was collectedjobsite
Where the material sample would have been placed if not sampledjobsite Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-08-14-113
DIME Test ID: 2025-08-14-113-2
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2025-09-17

Test Results


Is oversize material: No
Input Type: Measured
Tester's full name: Rigoberto Arroyo
Date of test: 08/14/2025
In-place wet density: 2.08
Highest adjust wet density: 2.14
% Moisture: 8.3 %
Optimum Moisture: 10.3 %
Relative compaction: 97
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/17/2025 ✔