Summary for Test 2017-11-09-3-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date11/09/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing11/28/2017 Sample typeQuality Assurance
A brief description of the sample7/8 2 1/2 A325 Bolt Assembly The quantity of what the sample constitutes7
From where was the sample collectedSource First name of sampler or witnessed byTory
Last name of sampler or witnessed byMcLaurin Title of samplerQA Inspector
Telephone number of sampler6616185971 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSt louis Screw Bolt
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL67-245-17
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0095159
Heat Number(s)10460750 Nut Mfg. Lot Number(s)23849-75063409
Washer Mfg. Lot Number(s)D3436 Bolt SpecificationA325
Bolt Length(s)2 1/2" Nut SpecificationA563 DH
Washer SpecificationF436 FinishMechanical Galvanizing
Diameter/Size7/8" Bolt Mfg. Lot NumberBM0501
Rocap Test Requirement(s) Lubricant Requirements(s)Blue
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2017-11-09-3
DIME Test ID: 2017-11-09-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-12-12

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/29/2017
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AB67-245-177/8\"6429628610A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 12/5/2017 ✔