Summary for Test 2017-11-09-3-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 11/09/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/28/2017 | Sample type | Quality Assurance |
| A brief description of the sample | 7/8 2 1/2 A325 Bolt Assembly | The quantity of what the sample constitutes | 7 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Tory |
| Last name of sampler or witnessed by | McLaurin | Title of sampler | QA Inspector |
| Telephone number of sampler | 6616185971 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | St louis Screw Bolt |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-245-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0095159 |
|---|---|---|---|
| Heat Number(s) | 10460750 | Nut Mfg. Lot Number(s) | 23849-75063409 |
| Washer Mfg. Lot Number(s) | D3436 | Bolt Specification | A325 |
| Bolt Length(s) | 2 1/2" | Nut Specification | A563 DH |
| Washer Specification | F436 | Finish | Mechanical Galvanizing |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | BM0501 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2017-11-09-3
DIME Test ID: 2017-11-09-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-12-12
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/29/2017
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | B67-245-17 | 7/8\" | 64296 | 286 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 12/5/2017 ✔