Summary for Test 2025-08-13-71-9
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1000211 DEA: 112N0204 EFIS: 1117000168 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-76-R17.2/24.1 |
| Award Date | 06/14/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AND OVERLAY WITH RHMA GAP GRADED. |
| Location Description | SAN DIEGO COUNTY NEAR PALA FROM ROUTE 76/15 SEPARATION TO PALA MISSION ROAD |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 08/13/2025 | Sample Unique Key | 71 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2025 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-08-13-71-PSU | Linked DIME Sample ID | 2025-08-13-70 |
| The fabricator/manufacturer/facility name | Vulcan Corona | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 326122 Otay SJR |
Test Details
DIME Sample ID: 2025-08-13-71
DIME Test ID: 2025-08-13-71-9
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2025-09-17
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/16/2025
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1410.0 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 38.0 grams | 97 % | |||||
| 234.0 grams | 83 % | |||||
| 864.0 grams | 39 % | |||||
| 1115.5 grams | 21 % | |||||
| 1232.5 grams | 13 % | |||||
| 1294.5 grams | 8 % | |||||
| 1332.0 grams | 6 % | |||||
| 1354.6 grams | 4 % | |||||
| 1366.9 grams | 3.1 % | |||||
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 9/17/2025 ✔