Summary for Test 2025-08-18-48-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 1000783 DEA: 041Q7004 EFIS: 0418000319 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-101-22.8/32.8 |
| Award Date | 02/06/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE BRIDGE RAILING AND GUARDRAIL, & RECONSTRUCT SIDEWALK. |
| Location Description | SONOMA COUNTY AT VARIOUS LOCATIONS FROM MENDOCINO AVENUE OVERCROSSING TO LIMERICK LANE OVERCROSSING |
| QA Service Level | 1 (Verified on 12/09/2024) |
Sample Information
| Sample Taken Date | 08/18/2025 | Sample Unique Key | 48 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/26/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 590CR2 | The quantity of what the sample constitutes | 10 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Jose |
| Last name of sampler or witnessed by | Calderon | Title of sampler | |
| Telephone number of sampler | 9164252912 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Superior Supplies Ready Mix | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 590CR2 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 311692 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-08-18-48
DIME Test ID: 2025-08-18-48-1
Testing Lab: Kleinfelder - Hayward
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-09-16
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: RD
Date of test: 09/15/2025
Capped in accordance with?: ASTM C39 - Ground End
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 53816 lb
Maximum load on cylinder 2: 56818 lb
Maximum load on cylinder 3: 52095 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4261.0 psi
Compressive strength of cylinder 2: 4498.7 psi
Compressive strength of cylinder 3: 4124.7 psi
Compressive strength (to nearest 10 psi): 4290 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/16/2025 ✔