Summary for Test 2025-08-26-66-2
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 1001059 DEA: 112N2334 EFIS: 1124000191 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5,15-Var |
| Award Date | 05/22/2025 |
| Closeout Date | 05/29/2026 |
| Work Description | MICROSURFACING, COLD PLANE, HMA TYPE A, SIGN INSTALLATION & STRIPING. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/30/2025) |
Sample Information
| Sample Taken Date | 08/26/2025 | Sample Unique Key | 66 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/02/2025 | Sample type | Verification |
| A brief description of the sample | SS-1H 1jug tack coat emulsion | The quantity of what the sample constitutes | 2qt, one container |
| From where was the sample collected | Source | First name of sampler or witnessed by | B. CARROLL |
| Last name of sampler or witnessed by | B. CARROLL | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | DISTRIBTOR TRUCK | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | N/A |
Test Details
DIME Sample ID: 2025-08-26-66
DIME Test ID: 2025-08-26-66-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphaltic Emulsion)
Test Release Date: 2025-09-17
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Was test performed on residue from distillation or evaporation?: Evaporation
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/11/2025
Ductility of test #1 (D1): 750 mm
Ductility of sample: 750 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/17/2025 ✔