Summary for Test 2025-09-09-50-1
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 1001063 DEA: 033G3804 EFIS: 0324000122 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-R23.9/30.8,31.0/31.6 |
| Award Date | 05/27/2025 |
| Closeout Date | Not set |
| Work Description | HMA OVERLAY, COLD PLANE, AND REMOVE & REPLACE PVMT DELINEATION. |
| Location Description | BUTTE COUNTY NEAR CHICO FROM NOPEL AVENUE TO 1.3 MILES WEST OF CARPENTER RIDGE ROAD AND FROM 1.1 MILES WEST OF CARPENTER RIDGE ROAD TO 0.5 MILE WEST OF CARPENTER RIDGE ROAD |
| QA Service Level | 1 (Verified on 03/19/2025) |
Sample Information
| Sample Taken Date | 09/09/2025 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2025 |
| Sample type | Quality Assurance | A brief description of the sample | SS1H 80/20 |
| The quantity of what the sample constitutes | 1 jug | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Emile | Last name of sampler or witnessed by | M |
| Title of sampler | Inspector | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Valero | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | 801938 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | SS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | 80/20 |
Test Details
DIME Sample ID: 2025-09-09-50
DIME Test ID: 2025-09-09-50-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2025-09-16
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Luis Maca
Date of test: 09/15/2025
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 143.2 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 118.7 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 141.8 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 117.6 g
Beaker 1 Residue: 49.0 %
Beaker 2 Residue: 48.4 %
Percentage of residue: 49 %
General comments (publicly viewable) (Max 1000 characters): Evap
Test was verified on 9/16/2025 ✔