Summary for Test 2017-11-20-1-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 211669 DEA: 022C0904 EFIS: 0200000161 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-50.6/51.7 |
| Award Date | 11/16/2016 |
| Closeout Date | 11/12/2020 |
| Work Description | BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT |
| Location Description | PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD |
| QA Service Level | 1 (Verified on 10/25/2016) |
Sample Information
| Sample Taken Date | 11/20/2017 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/20/2017 |
| Sample type | Quality Assurance | A brief description of the sample | 1 x 30 A449 All thread assembly |
| The quantity of what the sample constitutes | One lot | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
| Title of sampler | QA Inspector | Telephone number of sampler | 5105900116 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Portland Bolt Manufacturing | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S28-345-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | A164782 | Nut Mfg. Lot Number(s) | 26288-6214401705 |
| Washer Mfg. Lot Number(s) | Nucor/PBM | Bolt Specification | A449 |
| Bolt Length(s) | 30 | Nut Specification | A563 |
| Washer Specification | A36 | Finish | HDG |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | Vulcan |
| Rocap Test Requirement(s) | No | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-11-20-1
DIME Test ID: 2017-11-20-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-12-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/28/2017
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1A | A449 !\" x 30 Allthreaded Rod With Nut | 0.606 | 82996 | 369 | 136957 | 124140 | 75229 | A449 Rod & Nut |
General comments (publicly viewable) (Max 1000 characters): A449 Rod & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 11/29/2017 ✔