Summary for Test 2025-09-10-30-6
Test performed: AASHTO T324-14Project Information
| Project Identifiers | Project ID: 1000682 DEA: 09379104 EFIS: 0919000005 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395-91.6/100.8 |
| Award Date | 02/20/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT HMA, CURB RAMPS, AND ELECTRICAL SYSTEMS. |
| Location Description | INYO COUNTY AT AND NEAR BIG PINE FROM 0.1 MILE SOUTH OF ELNA ROAD TO SOUTH JUNCTION ROUTE 168 |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 09/10/2025 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/11/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" HMA-A-SP PG58-34M R18 | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Colton |
| Last name of sampler or witnessed by | Carrington | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | HMA-104 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | RHB Plant Independence | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-09-10-30
DIME Test ID: 2025-09-10-30-6
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2025-09-12
Test Results
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 09/12/2025
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 20 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 4.49 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.57 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
General comments (publicly viewable) (Max 1000 characters): HMA-104
Test was verified on 9/12/2025 ✔