Summary for Test 2017-11-14-5-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/14/2017 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/17/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Anchor Rods Nuts Washers |
The quantity of what the sample constitutes | 20 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | (562) 229-9279 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | A and M Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3066144 | Nut Mfg. Lot Number(s) | 26144-177467 |
Washer Mfg. Lot Number(s) | 300275 | Bolt Specification | F1554 Grade 55 |
Bolt Length(s) | 36" | Nut Specification | A194 |
Washer Specification | F436 | Finish | Hot-dip galvanized |
Diameter/Size | 1-1/2" | Bolt Mfg. Lot Number | 40423 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | None |
Test Details
DIME Sample ID: 2017-11-14-5
DIME Test ID: 2017-11-14-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-12-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/28/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | L08 | 1 1/2\" | 249440 | 1109.56 | Nut Proof | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point FileTest was verified on 11/29/2017 ✔