Summary for Test 2025-08-13-78-4

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 1001282
DEA: 022J8604
EFIS: 0221000142
DIST-CO-RTE-PM02-SHA-5-61.75/61.75
Award DateNot set
Closeout DateNot set
Work DescriptionSweetbrier Deck Replacement - Bridge Rehabilitation and Replacement
Location DescriptionIn Shasta County near Castella at Sweetbrier Overcrossing Bridge #06-0115
QA Service Level1 (Verified on 05/27/2025)

Sample Information

Sample Taken Date08/13/2025 Sample Unique Key78
Date that the sample was received by the laboratory/organization performing the testing08/14/2025 Sample typePreliminary
A brief description of the sampleSand, Silt, Rock and Soil The quantity of what the sample constitutesNot Provided
From where was the sample collectedSource First name of sampler or witnessed byBrian
Last name of sampler or witnessed bySteiner Title of samplerAssistant DME
Telephone number of sampler Laboratory sample identificationD80002
Linked DIME Sample ID The fabricator/manufacturer/facility nameRoadside
Transportation Laboratory (TL) Number858148 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedShoulder Slope near SHA 5 PM 61.75 at the NB Sweetbrier offramp
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-08-13-78
DIME Test ID: 2025-08-13-78-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2025-09-03

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/21/2025
Minimum soil resistance of the lab measurement: 8800 Ohms
Soil sample temperature: 19.6 C
Soil box constant: 1
pH of soil: 6.27
Minimum soil resistance corrected to 15.5: 9702 Ohm-cm
Minimum soil resistivity at 15.5: 9702 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.27, p=9702.Ω∙cm

Test was verified on 9/3/2025 ✔