Summary for Test 2025-07-14-119-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000575
DEA: 11430904
EFIS: 1119000199
DIST-CO-RTE-PM11-SD-5,805-Var
Award Date02/12/2025
Closeout DateNot set
Work DescriptionRESURFACE BRIDGE, REPLACE BRIDGE BARRIER, MGS, AND MODIFY ELECT.
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/04/2025)

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key119
Date that the sample was received by the laboratory/organization performing the testing07/15/2025 Sample typeQuality Control
A brief description of the samplesc The quantity of what the sample constitutescy
From where was the sample collectedSource First name of sampler or witnessed byKristian
Last name of sampler or witnessed byLopez Title of samplerQC Technician
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertsons Ready Mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameBarrier Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM20135
The truck number from where the sample was collected2254 The batch plant ticket number from where the sample was collected1561707
Concrete batch plantOtay Mesa The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSB Rte805, Barrier Wall Where the material sample would have been placed if not sampledSB Rte805, Barrier Wall
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-07-14-119
DIME Test ID: 2025-07-14-119-2
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-09-03

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Jesse Lara
Date of test: 08/11/2025
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Average cylinder density (to nearest 1 pcf): 149.3 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): Avg Comp Strength - 4150psi

Test was verified on 9/3/2025 ✔