Summary for Test 2025-08-19-62-2

Test performed: ASTM D217-21

Project Information

Project IdentifiersProject ID: 994962
DEA: 07357304
EFIS: 0719000062
DIST-CO-RTE-PM07-LA-5-6.6/13.1
Award Date04/27/2023
Closeout Date05/29/2026
Work DescriptionREPLACE CONCRETE SLABS AND MEDIAN BARRIER,
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, DOWNEY AND CITY OF COMMERCE FROM 0.2 MILE SOUTH OF ROUTE 5/605 SEPARATION TO 0.1 MILE NORT
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date08/19/2025 Sample Unique Key62
Date that the sample was received by the laboratory/organization performing the testing08/21/2025 Sample typeVerification
A brief description of the sampleAsphalt Rubber Binder The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byAlvaro
Last name of sampler or witnessed byFanetti Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2025-08-19-62
DIME Test ID: 2025-08-19-62-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-21: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2025-09-09

Test Results


Determination: Unworked Penetration
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 08/28/2025
Unworked Penetration: 33 0.1 mm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/9/2025 ✔